Hioki RM3543 电阻计(10mΩ~1000Ω)

Specification
Measurement method: Four-terminal, constant-current DC
Resistance range: 10 mΩ ~ 1000 Ω/1 mΩ resolution), 7 steps
Display: Monochrome graphic LCD 240 × 64 dot, white LED backlight
Measurement accuracy: [at 10 mΩ range, with SLOW mode, average 16 times settings] ±0.060 % rdg. ±0.001 % f.s.
Testing current:[at 10 mΩ range] 1 A DC to [at 1000 Ω range] 1 mA DC
Open-terminal voltage:     20 V DC max
Sampling rate:     FAST, MEDIUM, SLOW, 3 settings
Integration time:[at 10 mΩ range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC,
Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz
Note: PLC = one power line cycle (mains wave-form period)
Other functions:Comparator, Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
Interface: External I/O, RS-232C, Printer, GP-IB (Model RM3543-01)
External I/O: Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output +5V, +12V, etc.
Power supply, consumption: 100 to 240 V AC, 50/60 Hz, 40 VA max.
Dimensions, mass: 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz)
Supplied accessories: Power cord ×1, EXT I/O male connector ×1, Operation manual ×1, Operation guide ×1
Warrancy: 12 month

Details
Measurement method Four-terminal, constant-current DC
Resistance range 10 mΩ (Max. 12.00000 mΩ, 0.01 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 7 steps
Display Monochrome graphic LCD 240 × 64 dot, white LED backlight
Measurement accuracy [at 10 mΩ range, with SLOW mode, average 16 times settings]
±0.060 % rdg. ±0.001 % f.s.
Testing current [at 10 mΩ range] 1 A DC to [at 1000 Ω range] 1 mA DC
Open-terminal voltage 20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 MΩ)
Sampling rate FAST, MEDIUM, SLOW, 3 settings
Integration time [at 10 mΩ range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC,
Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz
Note: PLC = one power line cycle (mains wave-form period)
Other functions Comparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
Interface External I/O, RS-232C, Printer, GP-IB (Model RM3543-01)
External I/O Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output +5V, +12V, etc.
Power supply, consumption 100 to 240 V AC, 50/60 Hz, 40 VA max.
Dimensions, mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz)
Supplied accessories Power cord ×1, EXT I/O male connector ×1, Operation manual ×1, Operation guide ×1