Hioki BT3563 电池测试仪

Specification
- Max. applied measurement voltage:
  + ±300 V DC rated input voltage
  + ±300 V DC maximum rated voltage above ground
- Resistance Measurement ranges
  + 3mΩ(max.3.1mΩ/resolution 0.1μΩ)~3000 Ω (Max.3100Ω/ resolution  100mΩ), 7 range/resolution : ±0.5 % rdg. ±5 dgt
  + Range 3mΩ/ resolution :±0.5 % rdg. ±10 dgt
  + Testing sound Frequency: 1kHz ±0.2Hz
  + Testing current: 100mA (Thang 3mΩ)~10μA (Thang 3000Ω)
  + Open-circuit Votalge: 25V(range 3/30 mΩ), 7V(range 300mΩ), 4V(range 3Ω~3000Ω)
- Voltage Measurement ranges:     DC 6 V(resolution 10μV)DC~300V(resolution 1mV), 3 range
- Display: 31000 full digits (resistance), 600000 full digits (voltage), LED
- Sampling rate: Four steps:4 ms(Extra-FAST), 12 ms(FAST), 35 ms(Medium), 150 ms(Slow)
- Measurement time: 10ms
- Comparator functions:
  + Setting: Upper and lower limit
  + Output: 3 levels (Hi, In, Lo) 
- Analog Output:      Measured resistance (displayed value, from 0 to 3.1V DC
- Interface: External I/O, RS-232C, Printer (RS-232C)
- Power supply: 100 to 240 V AC, 50/60 Hz, 30 VA max
- Dimensions, mass: 215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.4 kg (84.7 oz)
- Supplied accessories: Power cord × 1
- The warrnty preiod: 12 month

Details
  BT3563/BT3563-01 BT3562/BT3562-01
Max. applied measurement voltage ±300 V DC rated input voltage
±300 V DC maximum rated voltage above ground
±60 V DC rated input voltage
±70 V DC maximum rated voltage above ground
Resistance Measurement ranges 3 mΩ (Max. display 3.1000 mΩ, resolution 0.1 μΩ) to 3000 Ω (Max. display 3100.0 Ω, resolution 100 mΩ), 7 ranges
Accuracy: 30 mΩ to 3000Ω ranges, ±0.5 % rdg. ±5 dgt. (Add ±3 dgt. for EX.FAST, or ±2 dgt. for FAST and MEDIUM)
3 mΩ range, ±0.5 % rdg. ±10 dgt. (Add ±30 dgt. for EX.FAST, or ±10 dgt. for FAST, or ±5 dgt. for MEDIUM)
Testing source frequency: 1kHz ±0.2Hz, testing current: 100 mA (3 mΩ range) to 10 μA (3000Ω range)
Open-circuit Voltage: 25 V peak (3/30 mΩ ranges), 7 V peak (300 mΩ range), 4 V peak (3Ω to 3000Ω ranges)
Voltage Measurement ranges DC 6 V (resolution 10 μV) to DC 300 V (resolution 1 mV), 3 ranges DC 6 V (resolution 10 μV) to DC 60 V (resolution 100 μV), 2 ranges
Accuracy: ±0.01 % rdg. ±3 dgt. (Add ±3 dgt. for EX.FAST, or ±2 dgt. for FAST and MEDIUM)
Display 31000 full digits (resistance), 600000 full digits (voltage), LED
Sampling rate Four steps
4 ms(Extra-FAST), 12 ms(FAST), 35 ms(Medium), 150 ms(Slow)
(Typ., sampling time depends on supply frequency settings and function.)
Measurement time Response time + sampling rate, approx. 10 ms for measurements
(Response time depends on reference values and the measurement object.)
Comparator functions Setting: Upper and lower limit
Output: 3 levels (Hi, In, Lo) or (Pass, Fail), Open-collector(35V, DC50mA max), Display, Dual audible indicator
Analog Output Measured resistance (displayed value, from 0 to 3.1V DC, -01 suffix models only)
Interface External I/O, RS-232C, Printer (RS-232C), GP-IB(-01 suffix models only)
Power supply 100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions, mass 215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.4 kg (84.7 oz)
Supplied accessories Power cord × 1