For full functionality of this site it is necessary to enable JavaScript.

Hioki 3336-03 电能质量分析仪(2ch,GP-IB,D / A输出)

SPECIFICATIONS
- Measurement line type: 
   + Single-phase 2-wire, single-phase 3-wire
   + Three-phase 3-wire
- Measurement items: 
   + Voltage, Current, Active power, Apparent power, Reactive power
   + Power factor, Phase angle, Frequency, Efficiency
   + Current integration, Active power integration, Integrated time
   + Voltage waveform peak value, Current waveform peak value  
   + Voltage crest factor, Current crest factor, Time average current
   + Time average active power, Voltage ripple factor
   + Current ripple factor
- Measurement range:
   + Voltage range: AC/DC 15 V to 1000 V, 7 ranges
   + Current range: AC/DC 200 mA to 50 A, 8 ranges
   + Power range: 3.0000 W to 150.00 kW
- Basic accuracy(Active power):
   + ±0.1% rdg. ±0.1% f.s. (DC)
   + ±0.1% rdg. ±0.05% f.s. (45 Hz to 66 Hz, at Input < 50% f.s.)
   + ±0.15% rdg. (45 Hz to 66 Hz, at 50% f.s. ≤ Input)
- D/A output:
   + 16 channels, Level output DC ±2 V, Waveform output 1 V f.s
   + Level output, instantaneous waveform output(U,I,P)
   + Level output (apparent power, reactive power, power factor, or other)
   + High-speed active power level output
- Other functions:
   + AC+DC, AC+DC Umn, AC, DC, FND, Autorange, Average
   + VT or CT ratio settings, Synchronized control
   + MAX/ MIN, or other functions
- External interfaces:
   + RS-232C, GP-IB
   + LAN standard
- Power supply: 100 to 240 V AC, 50/60 Hz, 40 VA max
- Product Net Weight: 5.6 kg
- Product Size: 305*132*256mm
- Supplied accessories:
   + Instruction manual ×1
   + Measurement guide ×1
   + Power cord ×1
- The warranty period: 12 month
Details

  

Measurement lines Single-phase 2-wires, single-phase 3-wires, 3-phase 3-wires, (voltage / current measurement range set for each wiring mode)
Measurement items Voltage, Current, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency, Efficiency, Current integration, Active power integration, Integrated time, Voltage waveform peak value, Current waveform peak value, Voltage crest factor, Current crest factor, Time average current, Time average active power, Voltage ripple factor, Current ripple factor
Harmonic parameters Synchronization frequency range: 10 Hz to 640 Hz, Analysis order up to 50th
Harmonic voltage RMS value, Harmonic current RMS value, Harmonic active power, Total harmonic voltage distortion, Total harmonic current distortion, Voltage fundamental waveform, Current fundamental waveform, Active power fundamental waveform, Apparent power fundamental waveform, Reactive power fundamental waveform, Power factor fundamental waveform (displacement power factor), Voltage current phase difference fundamental waveform, Interchannel voltage fundamental wave phase difference, Interchannel current fundamental wave phase difference, Harmonic voltage content % , Harmonic current content % , Harmonic active power content %
(The following parameters can be downloaded as data during PC communication but not displayed: Harmonic voltage phase angle, Harmonic current phase angle, Harmonic voltage current phase difference)
Measurement range Voltage range: AC/DC 15 V to 1000 V, 7 ranges
Current range: AC/DC 200 mA to 50 A, 8 ranges
Power range: 3.0000 W to 100.00 kW (Depends on combination of voltage and current range)
Integration measurement
(Integration time up to 10,000 hours)
[Current] No.of displayed digits: 6 digits (from 0.00000 mAh, Polarityindependent integration and Sum value)
[Active power] No.of displayed digits: 6 digits (from 0.00000 mWh, Polarity-independent integration and Sum value)
Input resistance (50/60 Hz) Voltage: 2 MΩ, Current: 1 mΩ or less (direct input)
Basic accuracy (Active power) ±0.1% rdg. ±0.1% f.s. (DC)
±0.1% rdg. ±0.05% f.s. (45 Hz to 66 Hz, at Input < 50% f.s.)
±0.15% rdg. (45 Hz to 66 Hz, at 50% f.s. ≤ Input)
Display refresh rate 5 times per second to 20 second (depend on average times settings)
Frequency characteristics DC, 0.1 Hz to 100 kHz
D/A output (-02/-03 model only) 16 channels (selectable from following items), Level output DC ±2 V, Waveform output 1 V f.s.
Level output, instantaneous waveform output (voltage, current, active power)
Level output (apparent power, reactive power, power factor, or other)
High-speed active power level output
Functions [Rectification method] AC+DC, AC+DC Umn, AC, DC, FND, Autorange, Average, VT or CT ratio settings, Synchronized control, MAX/ MIN, or other functions
Interface RS-232C / LAN standard, (-01/-03 model also includes GP-IB)
Power supply 100 to 240 V AC, 50/60 Hz, 40 VA max.
Dimensions and mass 305 mm (12.01 in) W × 132 mm (5.20 in) H × 256 mm (10.08 in) D, 5.2 kg (183.4 oz)
Accessories Instruction manual ×1, Measurement guide ×1, Power cord ×1

OPTION

CLAMP ON SENSOR 9660
CLAMP ON SENSOR 9660 100A AC rated current, φ 15 mm (0.59 in), 3 m (9.84 ft) length
 
Details
CLAMP ON SENSOR 9661
CLAMP ON SENSOR 9661 500A AC rated current, φ 46 mm (1.81 in), 3 m (9.84 ft) length
 
Details
FLEXIBLE CLAMP ON SENSOR CT9667
CLAMP ON SENSOR 9661 5000/500 A AC rated current, φ 254 mm (10 in), Cable length: Between sensor - box 2 m (6.56 ft), Output cable 1 m (3.28 ft)
 
Details
CLAMP ON SENSOR 9669
CLAMP ON SENSOR 9661 1000A AC rated current, φ 55 mm (2.17 in), 3 m (9.84 ft) length
 
Details
Current measurement [Type 2]
Requires Sensor unit 9555-10 and Connection cord L9217 (1 sensor necessary for single-phase measurement, and 2 sensors required for 3-phase measurements)
AC/DC CURRENT SENSOR CT6865
AC/DC CURRENT SENSOR CT6865 CAT III 1000 V, 1000A AC/DC rated current, DC to 20kHz response, core dia. 36 mm (1.42 in), cord length 3 m (9.84 ft)
Details
AC/DC CURRENT SENSOR 9709
AC/DC CURRENT SENSOR 9709 CAT III 1000 V, 500A AC/DC rated current, DC to 100kHz response, core dia. 36 mm (1.42 in), cord length 3 m (9.84 ft)
Details
AC/DC CURRENT SENSOR CT6863
AC/DC CURRENT SENSOR CT6863 CAT III 1000 V, 200A AC/DC rated current, DC to 500kHz response, core dia. 24 mm (0.94 in), cord length 3 m (9.84 ft)
AC/DC CURRENT SENSOR CT6862
AC/DC CURRENT SENSOR CT6862 CAT III 1000 V, 50A AC/ DC rated current, DC to 1MHz response, core dia. 24 mm (0.94 in), cord length 3 m (9.84 ft)
UNIVERSAL CLAMP ON CT 9279
UNIVERSAL CLAMP ON CT 9279 600 Vrms insulated wire, 500A AC/DC rated current, DC to 20kHz response, core dia. 40 mm (1.57 in), cord length 3 m (9.84 ft), Not CE marked
Details
UNIVERSAL CLAMP ON CT 9278
UNIVERSAL CLAMP ON CT 9278 CAT II 600 Vrms, CAT III 300 Vrms, 200A AC/ DC rated current, DC to 100kHz response, core dia. 20 mm (0.79 in), cord length 3 m (9.84 ft)
Details
UNIVERSAL CLAMP ON CT 9277
UNIVERSAL CLAMP ON CT 9277 CAT II 600 Vrms, CAT III 300 Vrms, 20A AC/ DC rated current, DC to 100kHz response, core dia. 20 mm (0.79 in), cord length 3 m (9.84 ft)
Details
CLAMP ON SENSOR 9272-10
CLAMP ON SENSOR 9272-10 CAT III 600 Vrms, 20A/200A AC rated current, 1Hz to 100kHz response, core dia. 46 mm (1.81 in), cord length 3 m (9.84 ft)
Details
SENSOR UNIT 9555-10
SENSOR UNIT 9555-10 Power supply for the Current Sensor, used alone
Details
CONNECTION CORD L9217
CONNECTION CORD L9217 Cord has insulated BNC connectors at both ends, signal output use, 1.6 m (5.25 ft) length
PC communication
LAN CABLE 9642
LAN CABLE 9642 Straight-through cable with crossover cable, 5 m (16.41 ft) length
RS-232C CABLE 9637
9pin − 9pin, cross, 1.8m (5.91 ft) length
RS-232C CABLE 9638
9pin − 25pin, cross, 1.8m (5.91 ft) length
GP-IB CONNECTOR CABLE 9151-02
2m (6.56 ft) length
Other options
Synchronized control with the 9165

 

CONNECTION CORD 9165
CONNECTION CORD 9165 Cord has metallic BNC connectors at both ends, signal output use, 1.5 m (4.92 ft) length, Not CE marked
DOWNLOAD CATALOG
pdficon POWER METER PW3336/PW3337
product catalog.pdf (2.12 MB) (2013-06-26 updated)

 

 

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会